Alcatel-Lucent OmniSwitch 6860


 Alcatel-Lucent OmniSwitch® 6860 Stackable LAN komutatori (SLS) ir kompakti, augstas veiktspējas Gigabit Ethernet (GigE) un ar 10 GigE veiktspēju, kas ir paredzēti visprasīgākajiem tīkliem.
 Papildus augstajai veiktspējai, OmniSwitch (OS) 6860 (E) piedāvā uzlabotu QoS atbalstu, lietotāju autentifikāciju, dziļo pakešu pārbaudi (DPI) un visaptverošas drošības funkcijas.
 OmniSwitch 6860 saimes komutatori piedāvā arī 60W PoE atbalstu uz katru portu.

 OmniSwitch 6860 komutatoru saimes pieejamie modeļi:

  • OS6860E-P24
  • OS6860E-P48
  • OS6860E-24
  • OS6860E-48
  • OS6860E-U28
  • OS6860-P24
  • OS6860-P48
  • OS6860-24
  • OS6860-48
  OS6860-24 OS6860-48 OS6860-P24 OS6860-P48 OS6860E-24 OS6860E-48 OS6860E-P24 OS6860E-P48 OS6860E-U28
PORTS:                  
Gigabit port count 24  48 24 (PoE) 48 (PoE)  24 48 24 (PoE) 48 (PoE) 28 
1G/10G SFP+ 4 4 4 4 4 4 4 4 4
20G QSFP+ VFL ports 2 2 2 2 2 2 2 2 2
Out-of-band EMP port 0 0 0 0 1 1 1 1 1
PERFORMANCE:                  
Max raw fabric capacity 224 Gb/s   264 Gb/s 224 Gb/s  264 Gb/s 224 Gb/s  264 Gb/s 224 Gb/s 264 Gb/s 224 Gb/s
Throughput (at 64-byte packet) 154.9 Mpps  190.6 Mpps  154.9 Mpps  190.6 Mpps  154.9 Mpps  190.6 Mpps  154.9 Mpps 190.6 Mpps  160.9 Mpps
Power consumption (idle) 35.6 W  41.7 W  61.9 W 70.8 W  38.9 W 44.1 W 65.0 W 72.9 W 70.1 W
Power consumption (full load) 45.6 W  57.2 W   477 W 900 W  48.0 W 60.0 W 480 W 904 W 72.2 W
ENVIRONMENT:                  
Operating temperature 0°C to 45°C  0°C to 45°C   0°C to 45°C 0°C to 45°C  0°C to 45°C 0°C to 45°C 0°C to 45°C 0°C to 45°C 0°C to 45°C
Storage temperature -40°C to 85°C  -40°C to 85°C  -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C
Humidity (operating) 5% to 95%  5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95%
Humidity (storage) 5% to 95%  5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95%
IP: OS6860-24  OS6860-48  OS6860-P24  OS6860-P48  OS6860E-24  OS6860E-48  OS6860E-P24  OS6860E-P48  OS6860E-U28 
Multiple VRF check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi
Static routing check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi
Routing Information
Protocol (RIP) v1, v2
and RPIng
check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi
Open Shortest Path First
(OSPF) v2 v3 with
Graceful Restart
check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi
Intermediate System to
Intermediate System (IS-IS)
with Graceful Restart
check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi
Virtual Router Redundancy
Protocol (VRRPv2)(VRRPv3)
check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi check mark blue hi